Quick Summary

Portable sink winterisation means draining the tank, pump and hoses, then storing the unit above freezing so trapped water cannot crack it. Freezing water expands, so an unprotected unit can split a tank or joint. Draining and dry storage are the two steps that matter most.

  • Switch off, unplug and isolate any mains supply before touching the water lines.

  • Drain the fresh-water tank completely, then clear the hoses and any low loops.

  • Run the pump briefly with the tank empty, then switch it off.

  • Empty any waste tank, and leave drain valves and taps open while stored.

  • Use antifreeze only if your manufacturer approves the product, and flush before reuse.

Ready for a winter-proof basin?

Infinity Basins makes self-contained hot and cold hand wash sinks that need no mains water connection.

Table of Contents

Portable sink winterisation is the process of draining, protecting and storing a freestanding hand wash basin so that frozen water cannot crack its tank, pump or hoses. If you run a tattoo studio, beauty room or pop-up stall with an Infinity Basins unit, a few simple steps before the first hard frost will save you a costly repair. Self-contained basins run without mains water, so the water sitting inside the tank and lines is the part that needs protecting when temperatures fall.

This guide walks through the job from start to finish, in the order most people should do it.

How do you winterise a portable sink?

To winterise a portable sink, drain every drop of water from the tank, pump and hoses, then store the unit somewhere above freezing. Freezing water expands, which is why a sink left full can split a tank or crack a joint. Draining and drying are the two steps that matter most.

Work through the job in this order:

  • Switch off and unplug the unit before you touch any water lines.

  • Drain the fresh-water tank completely.

  • Clear the hoses and any low loops where water can sit.

  • Run the pump briefly to push out residual water, then switch it off.

  • Store the unit in a space that stays above freezing.

Watch out: a tank that looks empty can still hold water in its low points and hose loops. Tip the unit gently and check each low point before you put it away.

Tools and materials you need before you start

Gather everything before you begin, so you are not hunting for a towel with wet hands. Most of the job needs only basic kit.

  • A bucket or container large enough to catch the tank's water

  • Old towels or a sponge for drying surfaces

  • A small funnel or length of clean tube for clearing hoses

  • Any manufacturer drain plug or valve key supplied with your unit

  • Dry storage space above freezing

  • Winterising antifreeze, only if your manufacturer approves it (see the antifreeze section below)

Keep your unit's manual nearby. Model details, such as where the drain point sits, vary, and the manual is the final word.

How to drain a portable sink for winter

Draining is the core task, and it takes about 15 to 30 minutes for most freestanding units. The order matters: tank first, then lines, then basin, then pump. How you do each step depends on how your unit is fed, so identify your water system before you start.

Person in a warm jacket emptying a water tank for portable sink winterisation in a garden shed.

Identify your water system first. Portable sinks generally fall into one of five designs, and the drain procedure differs for each:

  • Gravity-fed units have a fresh-water tank mounted above the basin and rely on gravity, not a pump, to deliver water. There is usually a simple drain plug at the base of the tank and a tap on the basin. Drain the tank, open the tap, and let air enter through the tap so the line empties.

  • Pumped units use a small electric pump to draw water from a tank, often a self-contained unit with a waste tank below. You must drain the tank and then run the pump briefly with the tank empty to clear the pump head and delivery line.

  • Mains-connected units take a plumbed supply through a float valve or solenoid. Shut off the supply at the isolation valve first, then open a tap to release line pressure before disconnecting. Never drain a mains-fed unit without isolating the supply.

  • Hot-water units have a small heater or boiler in addition to the cold tank. Drain the hot side separately, and do not switch the heater on again until the unit is refilled, or you risk a dry-fired element.

  • Self-contained units with waste tanks need the waste tank emptied as well as the fresh tank. Waste water left in the tank can freeze and split it just as readily as fresh water.

Step-by-step drain procedure.

  1. Switch off and unplug the unit, and isolate any mains supply at the valve.

  2. Place a bucket under the fresh-water tank drain point. Open the drain valve or remove the drain plug.

  3. Let the tank empty fully. Tilt the unit slightly towards the drain point to reach the last of the water.

  4. Open the tap or valve on the basin so air can enter the lines. Water drains more freely when air can flow in.

  5. Empty the basin itself, then wipe it dry.

  6. On pumped units, run the pump for a few seconds with the tank empty to push residual water out of the pump head and delivery line, then switch it off.

  7. Empty the waste tank if your unit has one, and wipe it dry.

  8. Leave the drain valve open and the tap open while you store the unit, so any trapped water can escape.

Watch out: on a mains-connected unit, opening the drain before isolating the supply will simply refill the tank through the float valve as fast as you empty it. Isolate first, then drain.

Most people find the tank is the easiest part. The hard part is the hoses, which the next section covers.

Clearing the fresh-water tank and hose loops

Hose loops are the most common place for trapped water. A loop that dips below the rest of the line holds water even after the tank is empty, and that water can freeze and split the hose.

  • Lift each hose so the water runs out of the low point.

  • Blow gently into the hose or use a clean tube to push out any remaining drops.

  • Check the tank's inner corners for pooled water and wipe them dry.

  • Repeat the check the next day if the unit is stored in a cold room.

A common mistake is leaving a hose coiled on the floor. Hang the hoses so they run downhill to the drain point, not into a dip.

Protecting taps, valves and exposed pipework

Taps, valves and any exposed pipework are the weak points once the water is out. These parts often crack first because they hold small amounts of water in tight spaces.

  • Open each tap fully and leave it open.

  • Keep valves in the open position so they cannot trap water.

  • Wrap exposed pipework in a soft towel or foam sleeve if the storage space is cold.

  • Never store the unit in an unheated outbuilding or vehicle where frost can reach it.

The steps below summarise the main drain procedure and timings from the article.

Step

What to do

Time or frequency

Isolate and unplug

Switch off, unplug and isolate any mains supply

Before any draining

Drain fresh-water tank

Open drain valve or remove plug, tilt gently

Until empty

Open basin tap

Lets air enter so lines drain freely

During draining

Run pump briefly

Clears residual water from pump head

A few seconds, tank empty

Empty waste tank

Drain and wipe dry, if fitted

Before storage

Store with valves open

Leave drain and tap open while stored

Throughout storage

Whole drain job

Tank, lines, basin and pump

About 15 to 30 minutes

Portable sink pump winter care

Any water left inside the pump can freeze, so treat it with care before storage.

  • Run the pump briefly with the tank empty to clear residual water.

  • Switch the pump off and disconnect it from power before you handle it.

  • Store the pump upright and dry, not tilted or resting in water.

  • Check the pump housing for cracks before you use the unit again in spring.

If the pump seems weak in spring, do not assume it has failed for good. Check the inlet and outlet for trapped debris or ice fragments first.

Using antifreeze safely in a portable sink

Antifreeze can protect the lines in very cold conditions, but only use a product your manufacturer approves. The wrong product can damage seals, contaminate the water system or leave residue that is unsafe for hand washing.

What product to use.

How to apply it. Follow the manufacturer's dilution and quantity.

How to flush before reuse. Before the unit goes back into service in spring, flush the system with clean water until the water runs clear and shows no residue or odour.

Watch out: antifreeze protects the lines, not the tank walls or the pump housing. A unit stored in a frost pocket can still crack even with antifreeze in the lines, so pair the product with a frost-free storage spot.

Portable sink storage over winter

Storage decides whether your winterisation work pays off. The best spot is somewhere dry, sheltered and above freezing, such as an indoor store, a heated room or a garage that stays frost-free.

  • Keep the unit off concrete floors that draw cold upwards.

  • Stand the unit upright so no water pools in the tank or basin.

  • Cover the unit lightly to keep dust off, but leave it able to breathe so moisture does not build up.

  • Check the storage space every few weeks for temperature drops.

If your pop-up or studio space cannot stay above freezing, plan to drain the unit each time you pack it away. Quick, regular draining is safer than trusting one long-term fill to hold through the cold.

Restarting and leak-testing your portable sink in spring

When the weather warms, restart your unit with a leak test before you use it on clients or customers. A slow leak is easy to miss, and it can damage floors and furniture.

  1. Inspect the tank, hoses, valves and taps for cracks or split joints.

  2. Reconnect the hoses and close the drain valve.

  3. Fill the tank slowly and watch every joint for drips.

  4. Run the pump and check the water flow at the tap.

  5. Leave the unit running for 20 minutes and check again for leaks.

Once the unit passes, you can refill it for regular use. If a leak or fault does not clear up, contact Infinity Basins for help working out the next step.

Frequently Asked Questions

Should you drain a portable sink before storing it for winter?

Yes. Any water left in the tank, pump, hoses or basin can freeze, expand and split plastic components, and the damage often only shows when you restart the unit in spring. Drain the fresh-water tank completely, run the tap and pump until no water comes through, and tip the basin dry. Store the unit upright in a space that stays above freezing where possible. If you cannot keep it frost-free, draining is the single most useful step you can take.

How do you stop a portable sink from freezing?

Remove the water first, since an empty system cannot freeze. If the unit must stay in service, keep it indoors in a room that does not fall below freezing, avoid placing it against an exterior wall or in an unheated porch, and insulate the hoses and exposed pipework. Wrapping the lines in foam pipe lagging helps, but it will not protect a unit left outdoors overnight in sustained frost. Check the weather forecast before a cold snap and act early.

Can you leave a portable sink outside in freezing weather?

It is not advisable. Outdoor exposure to sub-zero temperatures and wind is the most common cause of frozen pipes and cracked tanks on portable units. Even a short overnight frost can damage a unit that still holds water. If the sink has to stay outside, drain it fully, disconnect the water supply, and consider a sheltered location out of direct wind, though an empty and drained unit is still safer than a full one.

How do you restart a portable sink after winter storage?

Before reconnecting, inspect the tank, hoses, taps and pump for cracks or split fittings. Refill the fresh-water tank, run the pump and taps for a few minutes to clear air and any residue, and check every joint and hose connection for drips. Carry out a short leak test with clean water before using the sink for clients or customers. If anything fails the check, replace the affected part rather than running the unit with a known fault.

 
 
 